Failure analysis finds out why an electronic part or assembly stopped working. The goal is a root cause that you can use to make a corrective action, for example a change to a design, a process or a supplier.
This category collects our case studies on many kinds of electronic parts. They include capacitors, diodes, transistors, integrated circuits, optocouplers and complete printed circuit boards. The common failure causes are electrical overstress (EOS), mechanical stress and cracking, moisture, contamination and process defects. In one case, a short on a board was caused by tin whiskers inside the solder mask. In another, cracks in ceramic capacitors came from PCB flexing.
A typical job starts with a review of the failure history and electrical tests on the failed parts, often compared with good parts. The lab then uses non-destructive methods such as X-ray radiography. Destructive steps follow, such as cross-sectioning and decapsulation, with optical and scanning electron microscopy. Chemical methods such as FTIR help to identify contamination.
To start a project, request a quote.
Wima versus Vishay Film Capacitor Comparison
Film capacitors are widely used because of their superior characteristics. This capacitor type is not polarized, which makes them suitable …
November 21, 2012Insitu Process Contamination
This filter is used in a water filter system for water consumption. The filters were plugging up rather fast with the pink material shown in …
July 10, 2012Copper Wire With Nickel Plated Pad
This is a picture of a copper wire that used to have tin plating and nickel plated pad. The wire was running 120V at 60Hz. The connection …
July 9, 2012Micro-hairs of Copper Oxide on Nickel Substrate
This a micrograph of copper oxide deposits on nickel plating. The copper oxide is inhibiting the electrical conduction of a 120V light on …
July 9, 2012Failure Analysis on Microwave Capacitors
The analysis was performed on ten failed microwave capacitors. They were Samwha vintage 2100VAC .65uF with 3 percent tolerance with a …
March 29, 2012EOS of Signal Diode
Gideon Analytical Laboratories received two integrated load switches and two small signal diodes for analysis. The integrated load switches …
January 4, 2012Strain Gauge Resistance Changes
Gideon Analytical Laboratories received an industrial scale to analyze possible manufacturing defects and potential problems that affect …
December 29, 2011Tin Whiskers
Gideon Analytical Laboratories performed analysis on several Melexis US2881 Sensors when the designer found shorts on the returned product …
September 17, 2011Phototransistor Failure
Gideon Analytical Laboratories received a failed SFH 320 optocoupler in a dual S0-8 package for failure analysis. Optocouplers can be used …
February 23, 2011Fire on Multilayer PCB
Gideon Analytical Laboratories received a PCB that had a fire in one section of the board. These PCBs can provide high-performance 10G …
June 30, 2010Optocoupler Failures
Gideon Analytical Laboratories received two failed photocouplers for failure analysis. These photocouplers feature a high isolation voltage, …
May 26, 2010Environmental Contamination of PCBs
Gideon Analytical Laboratories received three central air conditioner hubs. These air conditioners can are built for commercial or …
March 8, 2010