Failure analysis finds out why an electronic part or assembly stopped working. The goal is a root cause that you can use to make a corrective action, for example a change to a design, a process or a supplier.
This category collects our case studies on many kinds of electronic parts. They include capacitors, diodes, transistors, integrated circuits, optocouplers and complete printed circuit boards. The common failure causes are electrical overstress (EOS), mechanical stress and cracking, moisture, contamination and process defects. In one case, a short on a board was caused by tin whiskers inside the solder mask. In another, cracks in ceramic capacitors came from PCB flexing.
A typical job starts with a review of the failure history and electrical tests on the failed parts, often compared with good parts. The lab then uses non-destructive methods such as X-ray radiography. Destructive steps follow, such as cross-sectioning and decapsulation, with optical and scanning electron microscopy. Chemical methods such as FTIR help to identify contamination.
To start a project, request a quote.
Shorted PX6A07 Silicon Rectifiers
Gideon Analytical Laboratories received several shorted PX6A07 silicon rectifiers for failure analysis. Two good devices were provided for …
February 26, 2006Silicon Rectifier PX6A07
This is a 6 amp plastic encapsulated silicon rectifier (PX6A07). Several of these high current diodes failed in the application. The arrow …
February 26, 2006Stranded Wire With High Resistance
Gideon Analytical Laboratories received two 42-inch cables. One cable labeled with a mark where an intermittent open occurred and the other …
July 11, 2005Polymeric O-ring Identification
Gideon Analytical Laboratories received three contaminated Buna-N diaphragms and several new ones for reference. These Buna-N diaphragms …
June 3, 20051N4148 Glass Diode Failures
Gideon Analytical Laboratories received several intermittent diodes failures and two good ones for comparison. The failed devices were …
April 27, 2005Printed Circuit Board Flexing During Depanelization
Gideon Analytical Laboratories received two printed circuit boards (PCB) with the questionable failure of multilayer ceramic capacitors in …
March 10, 2005Liquid Contamination on Relays
Gideon Analytical Laboratories performed failure analysis on several Sky CKC-1C-12VDC 12A/120V relays. These relays have a contact …
March 8, 2005Solder Joint Strain Failures
Gideon Analytical Laboratories performed failure analysis on two printed circuit board assemblies (PCB) with fractured solder joints on the …
November 12, 2004Bourns RJR26 Potentiometer Failure
Gideon Analytical Laboratories performed failure Analysis on a failed RJR26 Bourns Potentiometer. The application failure was noticed when a …
June 28, 2004Kemet T491C155M035AT Tantalum Capacitors
Gideon Analytical Laboratories received two surface mount T491C155M035AT Kemet tantalum capacitors with internal resistive shorts. These …
January 14, 2004IXYS IXGH32N60B Passivation Defect on IGBT
Gideon Analytical Laboratories performed failure analysis on several IXYS IGBT IXGH32N60B transistors, encased in TO-247 packages. These …
October 31, 2003Premature Discharge of Ansul IQ-396X Fire Circuitry
Gideon Analytical Laboratories performed failure analysis on one Ansul IQ-396X, which was submitted for possible failure due to an …
June 20, 2003