Failure analysis finds out why an electronic part or assembly stopped working. The goal is a root cause that you can use to make a corrective action, for example a change to a design, a process or a supplier.
This category collects our case studies on many kinds of electronic parts. They include capacitors, diodes, transistors, integrated circuits, optocouplers and complete printed circuit boards. The common failure causes are electrical overstress (EOS), mechanical stress and cracking, moisture, contamination and process defects. In one case, a short on a board was caused by tin whiskers inside the solder mask. In another, cracks in ceramic capacitors came from PCB flexing.
A typical job starts with a review of the failure history and electrical tests on the failed parts, often compared with good parts. The lab then uses non-destructive methods such as X-ray radiography. Destructive steps follow, such as cross-sectioning and decapsulation, with optical and scanning electron microscopy. Chemical methods such as FTIR help to identify contamination.
To start a project, request a quote.
Electronic Transformers
Gideon Analytical Laboratories received four electronic transformers, some of which were failing. Three transformers produced no output and …
January 27, 2017MH Ballast Black Box PCB
Gideon Analytical Laboratories received several electronic metal-halide (MH) ballast black semiconductor diode, but it also permits current …
January 27, 2017TDK-Lambda KPSA Power Supply
The Lambda KPSA10-15 is a self-contained, offline power supply capable of supply 15Volts DC at 1 Ampere from a universal input of 120VAC ~ …
January 27, 2017Soldering Problems Printed Circuit Boards
Gideon Analytical Laboratories received four Printed Circuit Boards which had either opens or intermittent behavior on some of the P1 …
November 12, 2016Leakage Current from MLCC on PCB
Gideon Analytical Laboratories received one failed multilayer ceramic capacitor (MLCC) on a printed circuit board (PCB). Multilayer ceramic …
June 16, 2016Fairchild Transient Voltage Suppressor SMBJ5VOCA
Gideon Analytical Laboratories received two Fairchild transient voltage suppressors (TVS) SMBJ5V0CA. Both diodes were identified as having …
October 24, 2014IR AUIRF7648M2 Power MOSFET
Gideon Analytical Laboratories received two failed AUIRF7648M2 MOSFETs. These are rather new on the market and specifically designed for the …
October 24, 2014Pulse Transformer 144A9111
Gideon Analytical Laboratories received two 144A9111 pulse transformers with the secondary wiring shorting. Transformers are devices that …
October 24, 2014Vishay ES2D SM Rectifier
Gideon Analytical Laboratories, Inc. received on Vishay ES2D rectifier on a PCB. The initial condition and observation were that the diode …
October 24, 20142N3700 Transistor
Gideon Analytical Laboratories received one 2N3700 transistor for failure analysis. A new 2N3700 transistor was also received for …
October 23, 2014Atmel AT91SAM9260 Based Embedded MPU
Gideon Analytical Laboratories, Inc. received Atmel AT91SAM9260 based Embedded MPU; it is a 180 MHz ARM926EJ-S ARM Thumb Processor. The …
October 23, 2014Melexis CMOS Hall Sensors
Gideon Analytical Laboratories received five failed Melexis US2881 in a UA style package for failure analysis. The Melexis US881 is a …
October 23, 2014