Failure analysis finds out why an electronic part or assembly stopped working. The goal is a root cause that you can use to make a corrective action, for example a change to a design, a process or a supplier.
This category collects our case studies on many kinds of electronic parts. They include capacitors, diodes, transistors, integrated circuits, optocouplers and complete printed circuit boards. The common failure causes are electrical overstress (EOS), mechanical stress and cracking, moisture, contamination and process defects. In one case, a short on a board was caused by tin whiskers inside the solder mask. In another, cracks in ceramic capacitors came from PCB flexing.
A typical job starts with a review of the failure history and electrical tests on the failed parts, often compared with good parts. The lab then uses non-destructive methods such as X-ray radiography. Destructive steps follow, such as cross-sectioning and decapsulation, with optical and scanning electron microscopy. Chemical methods such as FTIR help to identify contamination.
To start a project, request a quote.
Spectrum Control Pi Filter
Gideon Analytical Laboratories received a single failed Spectrum Control Pi filter on which to perform failure analysis. Capacitor-input …
July 1, 2013FCS RV4141V GFI Controller
Gideon Analytical Labs received two failed RV4141AM ground fault interrupter controllers. The devices had far different impedance values …
May 30, 2013Passivation Integrity Test on Transistors
Gideon Analytical Laboratories performed failure analysis on several IXYSIGBT IXGH32N60B transistors, encased in TO-247 packages. These …
May 27, 2013LCD Analysis
Gideon Analytical Laboratories received several liquid-crystal displays (LCDs) that had fading issues; there were five failing LCDs and a …
May 8, 2013NEC Inverter Board
Gideon Analytical Laboratories received three sample NEC 104PW161 power inverter boards for failure analysis. A power inverter is designed …
May 8, 2013Surface Mount Tantalum Capacitors
Gideon Analytical Laboratories received two surface mount (SM) tantalum capacitors that had internal resistive shorts. Capacitors are …
May 2, 2013CMOS RC Timer
Gideon Analytical Laboratories received two ICM7555 CMOS RC timers. Each device was pulling down the output. The ICM7556 is a CMOS RC timer …
April 24, 2013FTIR of LEDs
Gideon Analytical Laboratories received a Unity PLCC LED and was asked to perform FTIR analysis for the purpose of materials compatibility. …
April 24, 2013Thermal Evaluation (TMA and DSC)
Gideon Analytical Laboratories performed thermal mechanical analysis TMA and differential thermal analysis (DSC) on two plastics which …
April 24, 2013Quartz Crystal Oscillator
Gideon Analytical Laboratories received one failed surface mount device (SMD) 200 ECSH quartz crystal oscillator and a good SMD 200 ECSH for …
April 22, 2013Ion Chromatograph Analysis on Three Samples
Gideon Analytical Laboratories received three samples in polyethylene bottles to develop an analytical procedure for determining chloride …
April 19, 2013Flex Circuit Failure
Gideon Analytical Laboratories received three failed Kapton based flex circuits with opens in the trace lines. The origin of the open was …
April 18, 2013