Failure analysis finds out why an electronic part or assembly stopped working. The goal is a root cause that you can use to make a corrective action, for example a change to a design, a process or a supplier.
This category collects our case studies on many kinds of electronic parts. They include capacitors, diodes, transistors, integrated circuits, optocouplers and complete printed circuit boards. The common failure causes are electrical overstress (EOS), mechanical stress and cracking, moisture, contamination and process defects. In one case, a short on a board was caused by tin whiskers inside the solder mask. In another, cracks in ceramic capacitors came from PCB flexing.
A typical job starts with a review of the failure history and electrical tests on the failed parts, often compared with good parts. The lab then uses non-destructive methods such as X-ray radiography. Destructive steps follow, such as cross-sectioning and decapsulation, with optical and scanning electron microscopy. Chemical methods such as FTIR help to identify contamination.
To start a project, request a quote.
220 Picofarad AVX Capacitor
Gideon Analytical Laboratories received four 220 picofarad AVX capacitors for failure analysis. There are a variety of capacitors, including …
April 17, 2013Digital Signal Processors (DSPs)
Gideon Analytical Laboratories received eighteen digital signal processors (DSPs) for failure analysis. A DSP is a microprocessor …
April 17, 2013Failure Analysis of LM386 Op-amps
Gideon Analytical Laboratories received two semi-operational LM386 operational amplifiers for failure analysis. An operational amplifier …
April 17, 2013Pulse Transformers Failure Analysis
Gideon Analytical Laboratories received six pulse transformers, three of which were failures, three of which were reliable. The objective …
April 17, 2013Resistor Films
Gideon Analytical Laboratories received several amplifier units were supplied to ascertain the difference between a new vintage resistor, …
April 17, 2013UPS Filter Capacitor Failure Analysis
Gideon Analytical Laboratories received an Areovox Z26P6045M21 45uF 600V capacitor for failure analysis. Capacitors are passive two-terminal …
April 17, 2013Corrosion on Lead Screw Assembly
Gideon Analytical Laboratories received several contaminated lead screw assemblies. Also received were three insulin samples, one grease …
April 3, 2013Corrosion
Gideon Analytical Laboratories received metallurgical corrosion failures from lamp sockets. The materials and the insulation protection was …
April 2, 2013Siliconix Si4998DY MOSFET
Gideon Analytical Laboratories received several dual N-channel SO-9 Vishay Siliconix MOSFETs. MOSFETs are transistors used for amplifying or …
April 2, 2013Connector Failure
Gideon Analytical Laboratories received two failed terminal block electrical connectors from two different installation sites. These …
April 1, 2013Vertical Cavity Surface Emitting Laser
Gideon Analytical Laboratories received several VCSELs (vertical cavity surface emitting laser" with diminished light capacity over time for …
April 1, 2013BGA Failure Analysis on Static Transfer Switch
Gideon Analytical Laboratories received one static transfer switch (STS) Main Logic printed circuit board (PCB) assembly with two chips …
March 31, 2013