Flex Circuits

Success Stories

Corrosion on Polyimide and Silicone PSA

Corrosion on Polyimide and Silicone PSA

Gideon Analytical Laboratories received a flex circuit with a mystery corrosion on the polyimide and silicone pressure sensitive adhesive (PSA). There was corrosion by-product, and the silicone adhesive appeared more like a gelatinous material than a tactic PSA. Contrary to popular belief, flex circuits are not training for a future bodybuilding competition, they are a technology for assembling electronic circuits by mounting electronic devices on flexible plastic substrates, such as polyimide, PEEK or transparent conductive polyester film. Additionally, flex circuits can be screen printed silver circuits on polyester. Flexible electronic assemblies may be manufactured using identical components used for rigid printed circuit boards, allowing the board to conform to the desired shape, or to flex during its use. A polyimide is a polymer of imide monomers, and have been in mass production since 1955 due to their diverse applications. The goal was to figure out what the mysterious corrosive substance on the polyimide and silicone PSA on the flex circuit was.

Flex Circuit Failure

Flex Circuit Failure

Gideon Analytical Laboratories received three failed Kapton based flex circuits with opens in the trace lines. The origin of the open was not known. The opens in the trace lines were traced down on the Kapton to several eyelets where contact was supposed to be made.

No areas were distinguished and no anomalies were found suggesting a trace copper foil problem on any of the circuits received. A cross-section of the above trace line and eyelet demonstrates the trace line (the line in the middle) either has been dislodged from the barrel or was never connected.