An integrated circuit (IC) is an electronic circuit on one small chip, or die, of semiconductor material, normally silicon. An IC can have several billion transistors and other components on one die. The trace line width of each conductor gets smaller as technology advances, so small defects have a larger effect.
ICs fail for many reasons. Electrical overstress (EOS) and electrostatic discharge (ESD) can damage metal and oxide on the die. Contamination and moisture inside the package can cause leakage. Cracks, delamination and bond-wire damage can come from mechanical or thermal stress. Process defects in the die or the package can also cause failures in the field.
The case studies in this category cover logic ICs, a DSP, gate drivers, voltage regulators and optocouplers. They include a CMOS gate with its supply line pulled down, and optocouplers with internal contamination.
The lab starts with electrical tests and curve tracing, then uses X-ray radiography to look at the package without damage. Next we decapsulate the part and examine the die with optical microscopy and scanning electron microscopy.
If you have failed ICs, request a quote.
Fairchild 740L6000 Internal Contamination
Gideon Analytical Laboratories received four Fairchild 74OL6000 field failed Optocouplers along with three good (virgin green dot) devices …
July 1, 2013Single End AD73311L Processor
Gideon Analytical Laboratories received two AD73311L CMOS general purpose analog front end processors. Each device had external thermal …
May 31, 2013CMOS RC Timer
Gideon Analytical Laboratories received two ICM7555 CMOS RC timers. Each device was pulling down the output. The ICM7556 is a CMOS RC timer …
April 24, 2013FTIR of LEDs
Gideon Analytical Laboratories received a Unity PLCC LED and was asked to perform FTIR analysis for the purpose of materials compatibility. …
April 24, 2013Digital Signal Processors (DSPs)
Gideon Analytical Laboratories received eighteen digital signal processors (DSPs) for failure analysis. A DSP is a microprocessor …
April 17, 2013Failure Analysis of LM386 Op-amps
Gideon Analytical Laboratories received two semi-operational LM386 operational amplifiers for failure analysis. An operational amplifier …
April 17, 2013Siliconix Si4998DY MOSFET
Gideon Analytical Laboratories received several dual N-channel SO-9 Vishay Siliconix MOSFETs. MOSFETs are transistors used for amplifying or …
April 2, 2013Vertical Cavity Surface Emitting Laser
Gideon Analytical Laboratories received several VCSELs (vertical cavity surface emitting laser" with diminished light capacity over time for …
April 1, 2013Varactor Diode GVD30601-001
Gideon Analytical Laboratories received several GVD30601-001 super hyperabrupt junction tuning varactor diodes with a latent failure …
March 31, 2013Op-Amp Failure Analysis
Gideon Analytical Laboratories received four Maxim 4252EUA dual op-amps for failure analysis. Operational Amplifiers or Op-amps are one of …
December 2, 2012Failure Analysis of EDN337N FET
Gideon Analytical labs received one FDN337N-channel FET for failure analysis. The Drain-Source was reported shorted. Super SOTTM-3 N-Channel …
December 1, 2012Synchronous Buck Driver TI UCC27223PWP Failure Analysis
Gideon Analytical Laboratories received two failed TI UCC27223PWP and three vintage devices for comparison. Two 14 pin Dip TI UCC27223PWP …