Hitachi S-570 with IXRF EDS

This Hitachi SEM S-570 is currently installed and used as a backup. It basically has the same resolution as the Hitachi 3700 which is a current model. It has IXRF EDS software 1.4D which is current. The IXRF interface box to the SEM allows digitizing of all images coming from the SEM. The IXRF software will allow connection to various detectors as long as the proper interface cables are used. It has two rebuilt roughing pumps and a third Hitachi for backup. We had a sample port installed and allows the sample to enter without allowing air into the vacuum chamber. Switch time is a couple minutes. The unit is a LaB6 and kept under constant vacuum using an ion pump at 5kV. This typically is 10-6 torr . We also have an extra Wehnelt assembly with filament installed in case the filament blows. We also have a backscatter unit installed. We have all the manuals to the equipment installed on this unit. There is also a fluid cooler on the bottom of the column and run by a second independent unit. There are two scintillators, an upper and lower. The resolution on the EDS SiLi detector is 138ev. This was rebuilt. We have a parts and circuit manuals. We have a high voltage tester for measuring current. We recommend a Hitachi service rep for dismantling and preparing for move.

Cooler

Cooler

Ion Pump High Voltage Supply

Ion Pump High Voltage Supply

Air Compressor

Air Compressor

EDS interface detector box with display

EDS interface detector box with display

Extra Roughing Pump

Extra Roughing Pump

Roughing Pump

Roughing Pump

Neslab Diffusion Pump Cooler

Neslab Diffusion Pump Cooler

Computer for EDS Running Win7

Computer for EDS Running Win7

LaB6 Filament housing

LaB6 Filament housing

Roughing Pump for Sample Port

Roughing Pump for Sample Port

Ion Pump and Filament

Ion Pump and Filament

Sample Port

Sample Port

The Power supply with a backup power supply

The Power supply with a backup power supply

S-570 Operation Manual

S-570 Operation Manual

Detection Resolution EDS

Detection Resolution EDS

Roughing Pump Manual

Roughing Pump Manual

Stage and Chamber entrance

Stage and Chamber entrance

Air Compressor manual

Air Compressor manual

Extra Wehnelt Cap with Filament

Extra Wehnelt Cap with Filament

Freeze Finger for Cryogenics

Freeze Finger for Cryogenics

Various Stubs

Various Stubs

SEM Console

SEM Console

SEM Scan

SEM Scan

Wehnelt cap with the copper rings

Wehnelt cap with the copper rings

S-570 setup and working

S-570 setup and working

Spare parts

Spare parts

Operating Panel

Operating Panel

Ion High Voltage Supply

Ion High Voltage Supply

Column and Detector

Column and Detector

Parts for Cryogenics

Parts for Cryogenics

Air Compressor Manual

Air Compressor Manual

Backscatter Manual

Backscatter Manual

Resolution of Detector

Resolution of Detector

Port plugs, column adjustment knobs, and copper rings for head.

Port plugs, column adjustment knobs, and copper rings for head.

Parts List for roughing pump

Parts List for roughing pump

Operating Manual

Operating Manual

Extra tubing and parts for internal solenoids

Extra tubing and parts for internal solenoids

Backscatter Manual

Backscatter Manual

2nd Operating Manual

2nd Operating Manual

Circuit Diagrams for the S-570

Circuit Diagrams for the S-570

Instruction Manual for the specimen Exchange Port

Instruction Manual for the specimen Exchange Port

Parts List for the S-570

Parts List for the S-570

SEM Console

SEM Console

IXRF Interface box

IXRF Interface box

Detector and Digital Interface box

Detector and Digital Interface box

HIgh Voltage test Box PN 538-4141

HIgh Voltage test Box PN 538-4141

IXRF Software Manual

IXRF Software Manual

Manual

Manual