# Hitachi S-570 with IXRF EDS




This Hitachi SEM S-570 is currently installed and used as a backup. It basically has the same resolution as the Hitachi 3700 which is a current model. It has IXRF EDS software 1.4D which is current. The IXRF interface box to the SEM allows digitizing of all images coming from the SEM. The IXRF software will allow connection to various detectors as long as the proper interface cables are used. It has two rebuilt roughing pumps and a third Hitachi for backup. We had a sample port installed and allows the sample to enter without allowing air into the vacuum chamber. Switch time is a couple minutes. The unit is a LaB6 and kept under constant vacuum using an ion pump at 5kV. This typically is 10-6 torr . We also have an extra Wehnelt assembly with filament installed in case the filament blows. We also have a backscatter unit installed. We have all the manuals to the equipment installed on this unit. There is also a fluid cooler on the bottom of the column and run by a second independent unit. There are two scintillators, an upper and lower. The resolution on the EDS SiLi detector is 138ev. This was rebuilt. We have a parts and circuit manuals. We have a high voltage tester for measuring current. We recommend a Hitachi service rep for dismantling and preparing for move.

![Cooler](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01735.jpg 'Cooler')

![Ion Pump High Voltage Supply](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01731.jpg 'Ion Pump High Voltage Supply')

![Air Compressor](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01734.jpg 'Air Compressor')

![EDS interface detector box with display](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01737.jpg 'EDS interface detector box with display')

![Extra Roughing Pump](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01732.jpg 'Extra Roughing Pump')

![Roughing Pump](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01738.jpg 'Roughing Pump')

![Neslab Diffusion Pump Cooler](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01739.jpg 'Neslab Diffusion Pump Cooler')

![Computer for EDS Running Win7](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01736.jpg 'Computer for EDS Running Win7')

![LaB6 Filament housing](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01742.jpg 'LaB6 Filament housing')

![Roughing Pump for Sample Port](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01733.jpg 'Roughing Pump for Sample Port')

![Ion Pump and Filament](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01740.jpg 'Ion Pump and Filament')

![Sample Port](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01741.jpg 'Sample Port')

![The Power supply with a backup power supply](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01744.jpg 'The Power supply with a backup power supply')

![S-570 Operation Manual](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01768.jpg 'S-570 Operation Manual')

![Detection Resolution EDS](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01772.jpg 'Detection Resolution EDS')

![Roughing Pump Manual](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01763.jpg 'Roughing Pump Manual')

![Stage and Chamber entrance](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01743.jpg 'Stage and Chamber entrance')

![Air Compressor manual](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01775.jpg 'Air Compressor manual')

![Extra Wehnelt Cap with Filament](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01782.jpg 'Extra Wehnelt Cap with Filament')

![Freeze Finger for Cryogenics](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01783.jpg 'Freeze Finger for Cryogenics')

![Various Stubs](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01779.jpg 'Various Stubs')

![SEM Console](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01095.jpg 'SEM Console')

![SEM Scan](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01096.jpg 'SEM Scan')

![Wehnelt cap with the copper rings](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01781.jpg 'Wehnelt cap with the copper rings')

![S-570 setup and working](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01100.jpg 'S-570 setup and working')

![Spare parts](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01778.jpg 'Spare parts')

![Operating Panel](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01098.jpg 'Operating Panel')

![Ion High Voltage Supply](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01099.jpg 'Ion High Voltage Supply')

![Column and Detector](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01097.jpg 'Column and Detector')

![Parts for Cryogenics](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01780.jpg 'Parts for Cryogenics')

![Air Compressor Manual](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01776.jpg 'Air Compressor Manual')

![Backscatter Manual](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01762.jpg 'Backscatter Manual')

![Resolution of Detector](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01771.jpg 'Resolution of Detector')

![Port plugs, column adjustment knobs, and copper rings for head.](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01777.jpg 'Port plugs, column adjustment knobs, and copper rings for head.')

![Parts List for roughing pump](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01767.jpg 'Parts List for roughing pump')

![Operating Manual](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01766.jpg 'Operating Manual')

![Extra tubing and parts for internal solenoids](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01784.jpg 'Extra tubing and parts for internal solenoids')

![Backscatter Manual](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01773.jpg 'Backscatter Manual')

![2nd Operating Manual](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01769.jpg '2nd Operating Manual')

![Circuit Diagrams for the S-570](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01765.jpg 'Circuit Diagrams for the S-570')

![Instruction Manual for the specimen Exchange Port](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01764.jpg 'Instruction Manual for the specimen Exchange Port')

![Parts List for the S-570](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01761.jpg 'Parts List for the S-570')

![SEM Console](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01841.jpg 'SEM Console')

![IXRF Interface box](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01840.jpg 'IXRF Interface box')

![Detector and Digital Interface box](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01842.jpg 'Detector and Digital Interface box')

![HIgh Voltage test Box PN 538-4141](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01843.jpg 'HIgh Voltage test Box PN 538-4141')

![IXRF Software Manual](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01770.jpg 'IXRF Software Manual')

![Manual](https://res.cloudinary.com/dy3wlzuye/image/upload/f_auto,c_scale,w_300/GideonLabs/DSC01774.jpg 'Manual')

