Gideon Analytical Laboratories received four 220 picofarad AVX capacitors for failure analysis. There are a variety of capacitors, including ceramic, aluminum, film, and tantalum, but all serve the same purpose, which is to store electrical charge. They are passive electrical components with at least two electrical conductors separated by an insulator (dielectric). The four220 picofarad AVX capacitors were giving low resistance readings.
Failure analysis ensued. The four 220 picofarad AVX capacitors were inspected for mechanical cracks, which would propagate upon voltage; no cracks were found on the external ceramic.
Gideon Analytical Laboratories received eighteen digital signal processors (DSPs) for failure analysis. A DSP is a microprocessor architecturally designed to mathematically modify or improve a signal. DSPs are used in a variety of applications, including audio and speech signal processing or and sonar and radar signal processing. The goal in digital signal processing is to convert real-world analog signals into digital signals. Gideon Analytical Laboratories performed failure analysis on the DSPs.
Gideon Analytical Laboratories received two semi-operational LM386 operational amplifiers for failure analysis. An operational amplifier (op-amp) is a DC-coupled high-gain electronic voltage amplifier with a differential input and, usually, a single-ended output. Op-amps are linear devices that have all the properties required for DC amplification and are used in signal conditioning, filtering, or to perform a variety of mathematical operations. The op-amps received were reported to have quiescent current 2 to 3 times the normal value.
Gideon Analytical Laboratories received six pulse transformers, three of which were failures, three of which were reliable. The objective was to determine the cause of the failures and inspect the unused transformers for anything that could contribute to the cause of failures. Transformers are devices that transfer electric energy from one circuit to another, usually with a change in voltage. Pulse transformers are transformers optimized for transmitting rectangular electrical pulses. Ideally, pulse transformer designers try to minimize voltage droop, rise time, and pulse distortion.
Gideon Analytical Laboratories received several amplifier units were supplied to ascertain the difference between a new vintage resistor, which failed, and the older one, which functioned normally. A resistor is a passive electrical component that enacts electrical resistance in a circuit. These resistors were measured at 22 ohms.
Failure analysis was performed on the resistors. It was not known if the resistors were from the same vendor or whether the power dissipation of the thick film was the same.
Gideon Analytical Laboratories received an Areovox Z26P6045M21 45uF 600V capacitor for failure analysis. Capacitors are passive two-terminal electrical components used to store electricity in an electric field. Inside most capacitors, there are two metal plates separated by a non-conducting substance (dielectric). Filter capacitors are used for filtering undesirable frequencies and removing voltage or signal spikes in electronic circuits. They are utilized in a variety of applications. Gideon Analytical Laboratories performed failure analysis the Areovox Z26P6045M21 45uF 600V capacitor.
Gideon Analytical Laboratories received several contaminated lead screw assemblies. Also received were three insulin samples, one grease sample, and several new parts making up the lead screw assembly. Lead screws are designed to translate turning/rotary motion into linear motion. The contamination on the shaft of the assembly was primarily concentrated between the bearing and the ball seal. The goal was to identify and determine the cause of the contamination.
Gideon Analytical Laboratories primarily used FTIR and SEM-EDS analysis for diagnostics.
Gideon Analytical Laboratories received metallurgical corrosion failures from lamp sockets. The materials and the insulation protection was compared to distinguish the difference between the two lamp sockets. The lamp sockets were overheating and melting the wire insulation in the application. These sockets are a type of bi-pin lamp fitting. Bi-pin lamp fittings are for use in incandescent (especially halogen) and some fluorescent lights. MR16 refers to the lamp construction and overall diameter at its largest circumference.
Gideon Analytical Laboratories received several dual N-channel SO-9 Vishay Siliconix MOSFETs. MOSFETs are transistors used for amplifying or switching electronic signals. The MOSFET is the most common transistor in both digital and analog circuits, used in many scenarios where voltage conversion is necessary. These dual N-channel SO-9 Vishay Siliconix Si4980DY MOSFETs were received for component evaluation and environmental testing in a variety of conditions to determine any noticeable flaws or anomalies with the package, die, or electrical parameters.
Gideon Analytical Laboratories received two failed terminal block electrical connectors from two different installation sites. These terminal connectors connect two or more wires to a single connection point, providing a convenient method of connecting electrical wiring without splicing or physically joining the ends. The two connectors were identical in construction, and both appeared burned out from overpower.
The connector was cross-sectioned and SEM-EDS analysis performed. The screws in the terminal block connector typically are tin plated copper clad iron.